Graco Reactor 2 E-30 vs H-40 – which did you go with?

Table of Contents

Home Community Forum Equipment & Rigs Graco Reactor 2 E-30 vs H-40 – which did you go with?

  • This topic is empty.
Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #2721
    Gus Andersen
    Member

    Upgrading from a small proportioner and trying to decide between the E-30 and H-40. Primary work is residential – attics, walls, crawl spaces. Occasional light commercial. What are folks running?

    #2722
    Cindy Russo
    Member

    E-30 is plenty for residential. The H-40 makes sense for higher commercial output. For resi 30 lb/min is more than enough and you will appreciate the lower weight and portability.

    #2723
    Bob Tremblay
    Member

    Running an E-30 and have been very happy with it for 3 years. Had one issue with a heater element but Graco support was solid. Make sure you are running the recommended hose sizes.

    #2724
    Gus Andersen
    Member

    What hose setup are you running? I was planning on 50 feet of 3/8 inch with a 15 foot whip.

    #2725
    Bob Tremblay
    Member

    3/8 inch at that length should be fine. I run 75 feet of 1/2 inch to reduce pressure drop and heat loss over longer runs. The whip length is good at 15-20 feet.

    #2726
    Cindy Russo
    Member

    Also do not skimp on the heated hose. Unheated bulk hose is a false economy – you will fight temperature variance all day. Go full heated for the main run.

    #2728
    Gus Andersen
    Member

    Makes sense. Went with the E-30 and will spec full heated hose. Thanks for the input!

Viewing 7 posts - 1 through 7 (of 7 total)
  • You must be logged in to reply to this topic.

Uncategorized

Uncategorized

Uncategorized

REVIEWS YOU CAN RELY ON

Our Network

Spray foam insulation can crank up the performance of your homes—if you do it right. Check out our daily posts on the Foam Insulation and the Foam Insulation Market. We review each company and relay the information directly to you. Join our mailing list and have them sent directly to your email each and every day.
If you would like to know more about polyurea or spray foam, we recommend visiting ArmorThane
Mike T. (TX) posted in Contractor Talk: "Best temp settings for 2lb foam in summer heat"New article: "Spray Foam R-Value: The Complete Guide" — Read it nowSarah K. (OH) rated a contractor 5 stars in ClevelandWebinar: Cold Climate Installations — June 18 at 2PM EDT — Register Free28 new members joined this week!Texas Chapter Meetup: June 24 in Dallas — RSVP nowFoamPro_Dave replied: "Graco vs Gusmer after 8 years — my verdict"Mike T. (TX) posted in Contractor Talk: "Best temp settings for 2lb foam in summer heat"New article: "Spray Foam R-Value: The Complete Guide" — Read it nowSarah K. (OH) rated a contractor 5 stars in ClevelandWebinar: Cold Climate Installations — June 18 at 2PM EDT — Register Free28 new members joined this week!Texas Chapter Meetup: June 24 in Dallas — RSVP nowFoamPro_Dave replied: "Graco vs Gusmer after 8 years — my verdict"
👥 14,247 Members💬 312 Active This Week📰 131 Articles4.9/5 Rating📅 4 Events This Month
LIVE Community
Mike T. (TX) posted in Contractor Talk
2 min ago
Sarah K. (OH) asked in Ask An Expert
9 min ago
FoamPro_Dave replied in Equipment and Rigs
15 min ago
NewContractor2025 joined the community
32 min ago
Linda G. (OR) posted in Green Building
48 min ago
Join 14,247 Members Free